B–63173EN/03
8. CONNECTION TO SETTING AND DISPLAY UNIT
275
Details of display link cable J183
Power Mate i JD41
(PCR–EV20MDT)
CA72 on relay panel
(DBM–25S)
1 RXD 11 0V
2 *RXD 12 0V
3 TXD 13 RXTM1
4 *TXD 14 RXTM2
5 15 TXTM1
6 16 TXTM2
717
818
919
10 20
J183
1FG 14
2 (VDR) 15 0V
3 (VDG) 16 (0V)
4 (VDB) 17 0V
5 (VSYNC) 18 0V
6 (HSYNC) 19 (0V)
7 20 (0V)
8 TXD 21 (0V)
9 *TXD 22 RXD
10 23 *RXD
11 24
12 25
13
JD41
RXD
*RXD
TXD
*TXD
0V
0V
RXTM1
RXTM2
TXTM1
TXTM2
1
2
3
4
11
12
13
14
15
16
Shield
CA72
22
23
8
9
17
18
15
1
RXD
*RXD
TXD
*TXD
0V
0V
0V
Shell
FG
#28AWG
#28AWG
twisted pair
Recommended cable: A66L–0001–0284#10P (#28AWG 10 pairs, common shield) <Hitachi Cable, Ltd., Oki Electric Cable Co., Ltd.>
Recommended connector JD41/JD45/JD14 Connector: PCR–E20FS or PCR–E20FA
Housing: PCR–V20LA <Honda Tsushin>
Recommended connector CA72 Connector: DBM–25S Metal lock: D20418–J9 <Japan Aviation Electronics>
The total length of cables J182 and J183 is 50 m maximum.
NOTE
1 Connect pin 1, labeled FG, of the relay connector CA72 to the cabinet.
2 In interface JD41 of the Power Mate i, termination on the CNC side is done by connecting (13)
and (14), and (15) and (16). When one detachable LCD/MDI and one Power Mate i are
connected, connecting (13) and (14), and (15) and (16) leads to no problem.
3 Connecting the shell of connector CA72 to 0 V is to make the unit detachable. This connects
0 V of the CNC and 0 V of the detachable LCD/MDI first.