B–63834EN/02
8. DATA INPUT/OUTPUTOPERATION
479
15 Turn the power to the NC back on.
16 Release the EMERGENCY STOP button on the machine operator’s
panel.
All parameters are output in the defined format from the memory of the
CNC to a floppy or NC tape.
Procedure for Outputting Parameters
1 Make sure the output device is ready for output.
2 Specify the punch code system (ISO or EIA) using a parameter.
3 Press the EDIT switch on the machine operator’s panel.
4 Press function key
SYSTEM
.
5 Press chapter selection soft key
[PARAM] to display the parameter
screen.
6 Press soft key
[(OPRT)].
7 Press rightmost soft key
(continuous menu key).
8 Press soft key [PUNCH].
9 To output all parameters, press the [ALL] soft key. To output only
parameters which are set to other than 0, press the [NON–0] soft key.
10 Press soft key
[EXEC].
All parameters are output in the defined format.
Output format is as follows:
NP ;. . . .
N A1P A2P AnP ;. . . . . . . . . .
NP ;. . . .
N:Parameter No.
A:Axis No.(n is the number of control axis)
P:Parameter setting value .
To suppress the output of the following parameters, press the [PUNCH]
soft key then [NON–0] soft key.
Other than axis type Axis type
Bit type Parameter for which all bits
are set to 0
Parameter for an axis for
which all bits are set to 0.
Value type Paramter whose value is 0. Parameter for an axis for
which the value is 0.
8.6.2
Outputting Parameters
Explanations
D Output format
D Suppressing output of
parameters set to 0