B–63834EN/02
8. DATA INPUT/OUTPUTOPERATION
497
5 Press soft key [READ], then [EXEC].
The program is input with the program number specified in step 4
assigned.
To cancel input, press soft key [CAN].
To stop input prior to its completion, press soft key [STOP].
Outputting a program
1 Press soft key [PRGRM] on the ALL IO screen, described in Section
III–8.10.1.
2 Select EDIT mode. A program directory is displayed.
3 Press soft key [(OPRT)]. The screen and soft keys change as shown
below.
D A program directory is displayed only in EDIT mode. In all other
modes, the ALL IO screen is displayed.
O0001 N00010
EDIT
*
* * * * * * * * * * * *
14:46:09
F SRH READ PUNCH (OPRT)
>_
PROGRAM (NUM.) MEMORY (CHAR.)
USED : 60 3321
FREE : 140 127839
O0010 O0001 O0003 O0002 O0555 O0999
O0062 O0004 O0005 O1111 O0969 O6666
O0021 O1234 O0588 O0020 O0040
DELETE
4 Enter address O.
5 Enter a desired program number.
If –9999 is entered, all programs in memory are output.
To output a range of programs, enter O
, Ojjjj. The
programs numbered from
to jjjj are output.
When bit 4 (SOR) of parameter No. 3107 for sorted display is set to 1
on the program library screen, programs are output in order, starting
from those having the smallest program numbers.
6 Press soft key [PUNCH], then [EXEC].
The specified program or programs are output. If steps 4 and 5 are
omitted, the currently selected program is output.
To cancel output, press soft key [CAN].
To stop output prior to its completion, press soft key [STOP].
EXECCANSTOP
Procedure
EXECCANSTOP