APPENDIX
E. STATUS WHEN TURNING POWER ON,
WHEN CLEAR AND WHEN RESET
B–63834EN/02
742
E
STATUS WHEN TURNING POWER ON, WHEN CLEAR
AND WHEN RESET
Parameter 3402 (CLR) is used to select whether resetting the CNC places
it in the cleared state or in the reset state (0: reset state/1: cleared state).
The symbols in the tables below mean the following :
f:The status is not changed or the movement is continued.
×:The status is cancelled or the movement is interrupted.
Item When turning power on Cleared Reset
Setting
Offset value f f f
data
Data set by the MDI
setting operation
f f f
Parameter f f f
Various
Programs in memory f f f
data
Contents in the buffer
storage
× × f : MDI mode
× : Other mode
Display of sequence
number
f f (Note 1) f (Note 1)
One shot G code × × ×
Modal G code Initial G codes.
(The G20 and G21 codes return
to the same state they were in
when the power was last turned
off.)
Initial G codes.
(G20/G21 are not
changed.)
f
F Zero Zero f
S, T, M × f f
K (Number of repeats) × × ×
Work coordinate value Zero f f