APPENDIX
B–63834EN/02
G. ALARM LIST
753
Number ContentsMessage
5195 DIRECTION CAN NOT BE JUDGED When the touch sensor with a single contact signal input is used in the
direct input B function for tool offset measurement values, the stored
pulse direction is not constant. One of the following conditions exists:
· The stop state exists in offset write mode.
· Servo off state
· The direction varies.
· Movement takes place simultaneously along two axes.
5197 FSSB : OPEN TIME OUT The CNC permitted FSSB to open, but FSSB was not opened.
5198 FSSB : ID DATA NOT READ Temporary assignment failed, so amplifier initial ID information could not
be read.
5220 REFERENCE POINT
ADJUSTMENT MODE
A parameter for automatically set a reference position is set. (Bit 2 of
parameter No. 1819 = 1)
Perform automatic setting.
(Position the machine at the reference position manually, then perform
manual reference position return.)
Supplementary: Automatic setting sets bit 2 of parameter No. 1819 to 0.
5222 SRAM CORRECTABLE ERROR The SRAM correctable error cannot be corrected.
Cause:
A memory problem occurred during memory initialization.
Action:
Replace the master printed circuit board (SRAM module).
5227 FILE NOT FOUND A specified file is not found during communication with the built–in
Handy File.
5228 SAME NAME USED There are duplicate file names in the built–in Handy File.
5229 WRITE PROTECTED A floppy disk in the built–in Handy File is write protected.
5231 TOO MANY FILES The number of files exceeds the limit during communication with the
built–in Handy File.
5232 DATA OVER–FLOW There is not enough floppy disk space in the built–in Handy File.
5235 COMMUNICATION ERROR A communication error occurred during communication with the built–in
Handy File.
5237 READ ERROR A floppy disk in the built–in Handy File cannot be read from. The floppy
disk may be defective, or the head may be dirty. Alternatively, the Handy
File is defective.
5238 WRITE ERROR A floppy disk in the built–in Handy File cannot be written to. The floppy
disk may be defective, or the head may be dirty. Alternatively, the Handy
File is defective.
5257 G41/G42 NOT ALLOWED IN MDI
MODE
G41/G42 (cutter compensation C: M series, tool–nose radius com-
pensation: T series) was specified in MDI mode. (Depending on the set-
ting of bit 4 of parameter No. 5008)
5303 TOUCH PANEL ERROR A touch panel error occurred.
Cause:
1. The touch panel is kept pressed.
2. The touch panel was pressed when power was turned on.
Remove the above causes, and turn on the power again.