B–63445EN/01
3. INPUT AND OUTPUT OF DATA
81
4. Press
OFFSET
SETTING
key, and soft key [OFFSET] to display the tool
compensation amount screen.
5. Press soft key [(OPRT)] and
key.
6. Press [READ] key and [EXEC] key and data input is started.
1. Select the EDIT (editing) mode.
2. Display the data display screen by pressing
key.
3. Perform the same operation as for program input.
4. The input offset data will be displayed on the screen after completion
of input operation.
Confirm the following parameters. If 1 is set, set it to 0.
(Change it in Emergency stop or MDI mode).
#7 #6 #5 #4 #3 #2 #1 #0Address
3201 NPE RAL
#6 (NPE) When programs are registered in part program storage area,
M02,M30 and M99 are:
0 : regarded as the end of program.
l 1 : not regarded as the end of porgram.
#1 (RAL) When programs are registered:
l 0 : All programs are registered.
1 : Only one program is registered.
#7 #6 #5 #4 #3 #2 #1 #0Address
3202 NE9 NE8
#4 (NE9)l0 :Programs of 9000s can be edited.
#4 (NE9)l1 :Programs of 9000s are protected.
#0 (NE8)l0 :Programs of 8000s can be edited.
#0 (NE8)l1 :Programs of 8000s are protected.
1. Select EDIT (editing) mode.
2. Turn off the program protect (KEY3=1).
3. Press
PROG
key and press soft key [PRGRM] to select a part program
file.
4. Press soft
key ,[(OPRT)] and key.
5. Press soft key [READ] and [EXEC], then data input is started.
1. Select EDIT mode.
2. Press
to display the program screen.
D Procedure (DPL/MDI)
3.2.13
Inputting Part
Programs
D Procedure (CRT/MDI)
D Procedure (DPL/MDI)