3.DIMENSIONS SPECIFICATIONS B-65292EN/03
- 40 -
Model name Type No.(A06B-)
Power leads
cross-sectional
area
(mm
2
)
Number of
power leads
Diameter of
power leads
(mm)
Size of power
lead crimp
terminal
Power leads
Connection
α50L/25000iB 1615-B120#Z318 2 6 2.8 M4 Connection B
α80S/20000iB 1621-B120#Z312 2 6 2.8 M5 Connection E
α80M/15000iB 1623-B170#Z011 2 3 2.8 None Connection A
α80L/8000iB 1625-B170#Z011 2 3 2.8 M5 Connection A
α100S/12500iB 1641-B120#Z011 3.5 6 3.5 M5 Connection B
α112SS/20000iB 1661-B120#Z312 5.5 6 4.4 M6 Connection E
α112S/15000iB 1671-B120#Z311 14 6 6.5 M8 Connection E
α112M/15000iB 1673-B120#Z311 5.5 6 4.4 M6 Connection B
α112L/15000iB 1675-B100#Z311 14 6 6.5 M8 Connection D
α112LL/15000iB 1676-B100#Z311 14 6 6.5 M8 Connection D
α132M/14000iB 1713-B100#Z311 22 6 8.6 M8 Connection D
α132L/14000iB 1705-B140#Z311 14 12 6.5 M10 Connection H
α160S/13000iB 1721-B120#Z311 14 6 6.5 M6 Connection E
α160M/13000iB 1723-B120#Z311 14 6 6.5 M6 Connection E
α160L/13000iB 1725-B120#Z311 14 6 6.5 M6 Connection E
α160LL/13000iB 1726-B100#Z311 14 6 6.5 M8 Connection D
α180M/6000iB 1743-B100#Z011 14 6 6.5 M8 Connection D
α180L/6000iB 1745-B100#Z011 22 6 8.6 M8 Connection D
α180LL/8000iB 1746-B100#Z011 22 6 8.6 M8 Connection D
α200M/6000iB 1753-B120#Z313 22 6 8.6 M8 Connection E
α200L/6000iB 1755-B120#Z316 30 6 9.6 M10 Connection E
Standard type
α250M/3000iB 1773-B140#Z316 22 12 8.6 M8
Connection F
<3>-<4>
α40S/70000iB 1601-B120#Z618 2 3 2.8 M4 Connection B
α80S/40000iB 1631-B120#Y618 8 6 5.1 M8 Connection B
α100S/20000iB 1641-B121#X617 8 6 5.1 M8 Connection E
α112S/20000iB 1662-B120#Z317 14 6 6.5 M8 Connection E
α112M/20000iB 1673-B100#Y617 14 6 6.5 M8 Connection D
α112L/20000iB 1675-B100#Y617 14 6 6.5 M8 Connection D
α112L/25000iB 1675-B140#X627 8 12 5.1 M8 Connection G
α132L/25000iB 1705-B140#Y617 14 12 6.5 M10
Connection F
<1>-<4>
α160M/20000iB 1723-B140#Y627 14 12 6.5 M8
Connection F
<1>-<4>
α160L/20000iB 1725-B140#Y617 14 12 6.5 M8 Connection G
High speed type
α160LL/20000iB 1726-B140#Y617 14 12 6.5 M8
Connection F
<1>-<4>
NOTE
• The outer diameter of the thermistor leads (THR leads) is φ5.2±0.3mm. This cable consists of two wires (20AWG)
and one shield net-wire. Use the diameter of the thermistor lead (5.2) as the minimum bending radius.
• A crimp terminal is attached to each thermistor lead (THR lead).
• To obtain a rated output, use a cooling jacket or equivalent that shown in "3.4 COOLING JACKET". Motors are
developed with those cooling jackets. Refer to "3.4 COOLING JACKET".
• Refer to "2.3 POWER LEADS CONNECTIONS" in "II.INSTRUCTION" for details of power leads connection.
• Read "II.INSTRUCTION" before designing and assembling a spindle. The motor cannot be driven normally if
handle incorrectly.