OPERATION
B–64144EN/01
11. SETTING AND DISPLAYING DATA
653
Procedure for enabling/displaying parameter writing
1 Select the MDI mode or enter state emergency stop.
2 Press function key
OFFSET
SETTING
.
3 Press soft key
[SETING] to display the setting screen.
SETTING (HANDY) O0001 N00000
> _ S 0 T0000
MDI **** *** *** 16:05:59
[ OFFSET ] [ SETING ] [ WORK ] [ ] [ (OPRT) ]
PARAMETER WRITE = 1 (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–3:CHANNEL NO.)
SEQUENCE NO. = 0 (0:OFF 1:ON)
TAPE FORMAT = 0 (0:NO CNV 1:F10/11)
SEQUENCE STOP = 0 (PROGRAM NO.)
SEQUENCE STOP = 11(SEQUENCE NO.)
4 Move the cursor to PARAMETER WRITE using cursor keys.
5 Press soft key
[(OPRT)], then press [1: ON] to enable parameter
writing.
At this time, the CNC enters the P/S alarm state (No. 100).
6 After setting parameters, return to the setting screen. Move the cursor
to
PARAMETER WRITE and press soft key [(OPRT)] , then press
[0: OFF].
7 Depress the
RESET
key to release the alarm condition. If P/S alarm No.
000 has occurred, however, turn off the power supply and then turn it
on, otherwise the P/S alarm is not released.
See III–8 for setting parameters with external input/output devices such
as the Handy File.
Some parameters are not effective until the power is turned off and on
again after they are set. Setting such parameters causes P/S alarm 000.
In this case, turn off the power, then turn it on again.
Refer to the FANUC Series 0i/0i Mate Parameter Manual (B–64120EN)
for the parameter list.
Some parameters can be set on the setting screen if the parameter list
indicates ”Setting entry is acceptable”. Setting 1 for
PARAMETER
WRITE is not necessary when three parameters are set on the setting
screen.
Explanations
D Setting parameters with
external input/output
devices
D Parameters that require
turning off the power
D Parameter list
D Setting data