Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
1. DISPLAY AND OPERATION
75
Function Operation
Function
key
Mode
SETTING
PWE=1
KEY
SW
Offset data input f VAR
Offset data screen No. Data Number
INPUT Data INPUT
Macro variable data input f VAR
Macro variable screen No. Data
Number INPUT Data INPUT
Search
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Program number search EDIT / AUTO PRGRM
O Program number
Sequence number search AUTO PRGRM
After program number search; N Sequence
number
Address word search EDIT PRGRM
Word to be searched for
Search address only EDIT PRGRM
Address to be searched for
Parameter search DGNOS /
PARAM
PARAM screen No. Number INPUT
PMC parameter search DGNOS /
PARAM
DGNOS screen [PMC address] Number
INPUT
Pitch error compensation data
search
DGNOS /
PARAM
Pitch error compensation datascreen No.
Data Number INPUT
Offset data search VAR
Offset screen No. Data Number
INPUT
Macro variable data search VAR
Macro variable screen No. Data Number
INPUT
Diagnosis search DGNOS /
PARAM
DGNOS screen No. Number
INPUT
Editing
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
All program delete f EDIT PRGRM
O 9999 DELETE
One program delete f EDIT PRGRM
O Program number DELETE
Multiple block delete f EDIT PRGRM
N Sequence number DELETE
One block delete f EDIT PRGRM
EOB DELETE
Word delete f EDIT PRGRM
Search for word to be deleted DELETE
Word change f EDIT PRGRM After searching for word to be changed; New
data ALTER
Word insertion f EDIT PRGRM After searching for word after which word is to be
inserted; New data INSERT
Collation
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Program collation EDIT PRGRM
READ