Fanuc Power Mate i-D/H Maintenance Manual

1. DISPLAY AND OPERATION
B63175EN/03
76
Registration from external I/O
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Parameter input f EDIT or
emergency
stop
DGNOS /
PARAM
PARAM screen READ
Program input f EDIT PRGRM
READ
Pitch error compensation data
input
f EDIT DGNOS /
PARAM
Pitch error compensation data Screen
READ
Offset data input f EDIT VAR
Offset data screen READ
Macro variable data input f EDIT PRGRM
READ Mode AUTO Execute the loaded
program READ
Output to external I/O
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Parameter output EDIT DGNOS /
PARAM
PARAM screen WRITE
All program output EDIT PRGRM
O 9999 WRITE
One program output EDIT PRGRM
O Program number WRITE
Pitch error compensation data
output
EDIT DGNOS /
PARAM
Pitch error compensation datascreen
WRITE
Offset data output EDIT VAR
Offset screen WRITE
Macro variable data output EDIT VAR
Macro variable screen WRITE
Input/output to and from PMC offline Programmer (FAPT LADDER for PC)
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Ladder program input/output DGNOS /
PARAM
DGNOS screen READ or WRITE
Operation on host
Input/output is automatically Identified with
operation on host. (The baud rate is fixed to
9600 bps.)
Input/output to and from FANUC Handy File
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Program registration f EDIT PRGRM
N File number READ READ
All program output EDIT PRGRM
O 9999 WRITE
One program output EDIT PRGRM
O Program number WRITE
Search for beginning of file EDIT PRGRM
N File number or 9999 or 9998
READ
File delete f EDIT PRGRM
N File number WRITE
Program collation EDIT PRGRM
N File number READ READ

Leave a Reply