Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
1. DISPLAY AND OPERATION
77
Function Operation
Function
key
Mode
SETTING
PWE=1
KEY
SW
PMC parameterLadder program
input
f
Only when
PMC
Emergency
stop
DGNOS /
PARAM
DGNOS screen No. FileNumber
READ
Data type is automaticallyidentified.
(The baud rate is fixed to 4800 bps.)
PMC parameter output EDIT DGNOS /
PARAM
PMC parameter display No. File number
WRITE
Ladder program output DGNOS /
PARAM
DGNOS screen No. RFile number
WRITE
Switching of 1path mode (Power Mate iD) and 2path mode (Power Mate iD2)
Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Select Single path control
system to Dual paths control
system
Power ON _
S and 2
Select Dual paths control
system to Single path control
system
Power ON _
S and 1
NOTE
1 When above mentioned operation is done, all CNC data on the SRAM memory backupped
by a battery, such as tool offset data, macro variable and so on, are cleared and the parameters
are set the default value at shipping. So all CNC data should be set again.
2 Even when the above mentioned operation is done, the special parameters are not cleared.
3 The operation to select path control system should be done only when required. This operation
is not necessary at every poweron.
4 Even if you keep pushing both 2 and S keys during turning on power on the condition of
2 paths control system or keep pushing both 1 and S keys on the condition of 1 path control
system, SRAM data is also all cleared.
5 After the memory all clear operation, the selection data for path control is set to 1path control
system.
Switching between the 1path mode and 2path mode (Power Mate iD2)
Classification Function
KEY
SW
SETTING
PWE=1
Mode
Function
key
Operation
Path Change 2 path side to 1 path side _
H and 2
1 path side to 2 path side _
H and 1