Fanuc Power Mate i-D/H Maintenance Manual

1. DISPLAY AND OPERATION
B63175EN/03
78
The Power Mate i requires some items to be set using switches on the main
unit of the Power Mate i. When no setting/display unit is connected to
the Power Mate i, simple maintenance operations such as the display of
the status of the Power Mate i and save and restore operation of files in
a batch can be performed just using the main unit.
For details of the setting, display, and maintenance operations using the
main unit of the Power Mate i, see Appendix F.
The following items must be set on the main unit of the Power Mate i:
Item Outline
Memory all clear Memory all clear operation using the CRT/MDI
cannot clear all the memory area. After
mounting and dismounting the memory
module or replacing it, perform all clear
operation by using the main unit of the Power
Mate i.
Startup with HSSB board
connected
Even when the HSSB board is connected, you
may start the Power Mate i independently of
the personal computer or PANEL i. In such a
case, make this setting on the main unit of the
Power Mate i. (Usually, the Power Mate starts
after the personal computer or PANEL i starts.)
Connection of handy operators
panel
When connecting the handy operators panel,
make this setting using the main unit of the
Power Mate i. (The CRT/MDI and handy
operators panel use the same connector but
use different baud rates.)
Connection of DPL/MDI
operation package (boot
operation)
When the system cannot start normally, make
this setting to perform boot operation using the
DPL/MDI operation package.
Setting of device number for the
CRT sharing function
Set a device number for the CRT sharing
function by using the main unit of the Power
Mate i.
The following maintenance operations can be performed using the main
unit of the Power Mate i:
Item Outline
Save/restoration of SRAM data
in/from builtin FROM
When a PC board is replaced without
replacing fuses or dismounting/mounting the
memory module, SRAM data is copied.
Save/restoration in/from a
memory card in a batch
SRAM data, ladder programs, C executor user
programs, and macro executor user programs
are saved in and restored from a memory card
in a batch.
Switching between DPL/MDI
operation package and FAPT
LADDER II
In maintenance using a notebook PC,
switching between the DPL/MDI operation
package and FAPT LADDER II is performed.
1.11
LIST OF
OPERATIONS
(Power Mate i MAIN
UNIT)

Leave a Reply