1. DISPLAY AND OPERATION
B63175EN/03
98
Up to 10 consumable items can be registered for management. Their
remaining service time and count status are displayed on the status screen.
PERIODICAL MAINTENANCE O0001 N12345
(STATUS)
ITEM NAME REMAIN
*01 BATTERY FOR CONTROLLER 0H
@02 BATTERY FOR PULSECODER 5000H
03 FAN MOTOR 10000H
@04 LCD BACK LIGHT 720H
05
06
07
08
09
10
>_
EDIT *** ***** *** **** 19:27:05
[ ][ MAINTE ][ ][ ][ (OPRT) ]
[ CHANGE ][ ENTRY ][ CLEAR ][ +INPUT ][ INPUT ]
[ ][ ][ ][ CAN ][ EXEC ]
(1)Item name
The name of an item to be subjected to periodic maintenance is
specified under Item name.
Two methods can be used to specify item names. The first method uses
the menu screen, and the second, the MDI keypad.
(1)Method of using the menu screen
1 Place the cursor on the target item name, and press soft key
[ENTRY]. A menu screen appears. The menu screen is either
the machine or NC system menu screen.
2 Press soft key [MACHIN] or [NC]. A machine system menu
appears. It holds the names of consumables typical to the
machine system or NC system.
3 Place the cursor on a registered item name, and press soft key
[SELECT], then soft key [EXEC]. The status screen appears
again, enabling the selected item to be set up.
4 Press soft key [CAN]. The previous soft key displays appear
again.
5 Press soft key [MAINTE]. The status screen appears again.
Using the machine system menu screen requires that item names
be registered on the screen previously.
This can be done using two methods, (a) and (b).
(a) Programbased registration
Executing a program in the following format enables item
names to be registered on the machine system menu screen.
1.16.3
Status Screen Display
and Setting