Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
1. DISPLAY AND OPERATION
103
The setting screen lets you specify the service life, the remaining service
time, and count type for a registered item name.
It also displays the same count status information as displayed on the
status screen.
PERIODICAL MAINTENANCE O0001 N12345
(SETTING)
LIFE REMAIN COUNT TYPE
*01 10000H 0H ALL TIME
@02 20000H 5000H LIV TIME
03 32767H 10000H ––––––––
@04 1500H 720H RUN TIME
05
06
07
08
09
10
>_
EDIT *** ***** *** **** 19:27:05
[ CHANGE ][ TYPE ][ CLEAR ][ +INPUT ][ INPUT ]
[ EFFECT ][ ALL ][ LIV ][ RUN ][ CUT ]
[ ][ READ ][ PUNCH ][ ][ ]
(1)Service life
The service life of a consumable item is to be specified under Service
life.
First place the cursor on the service life of a target registration number,
enter a desired service life value using numeric keys, then press soft
key [INPUT] (or the
INPUT
key). The specified service life is set up,
and the same value is set up also under Remaining service time.
In addition, the count type for the item changes to: “––––––”
Pressing soft key [+INPUT] adds the newly specified service life value
to the previously specified life value. The added service life value is
reflected to the remaining service time.
The valid data range for the service life is: 0 to 65535 (hours)
NOTE
1 An attempt to set up the service life for a nonregistered
item results in the warning message EDIT REJECTED.
2 An attempt to enter a value that is out of the valid data range
results in the warning message DATA IS OUT OF RANGE.
3 An attempt to enter a value that would make the service life
or remaining service time 0 or lower, it is clamped at 0.
4 Pressing soft keys [CLEAR] and [TYPE] results in the
warning message EDIT REJECTED.
1.16.4
Setting Screen Display
and Setting

Leave a Reply