1. DISPLAY AND OPERATION
B63175EN/03
106
a : Service life
r : Remaining service time
n : Item name
[Alphanumeric characters*twobyte characters * alphanumeric
characters
q : count type
0 = not to count
1 = count at all times
2 = count during poweron time
3 = count during operation
4 = count during cutting
After the EDIT mode is selected, pressing soft key [READ] causes data
to be registered with item names according to the format in which the data
is input (G10).
Data registration can be done even by executing the format (G10) once
input to the program memory.
NOTE
If the input format (G10) differs from the output format,
registration may fail.
8911
Percentage to the service life of each item displayed on the periodic
maintenance screen
[Data type] Byte
[Unit of data] 1%
[Valid data range] 0 to 100
On the periodic maintenance screens, any remaining service time value
smaller than the specified percentage to the service life is displayed in
green for warning purposes (for a color LCD with touch panel).
D Data input