Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
2. HARDWARE
195
This section applies to the I/O module for connector (basic).
Table 2.7.11 (a) Drawing number of I/O module for connector
Name
Specification
I/O module for connector (basic) A03B0815C001
The I/O module for connector contains a 24 VDC power input fuse. If
power is not supplied to the I/O module for connector, this fuse may have
blown. In such a case, remove the fuse from its socket, then check its
continuity using a multimeter. When the fuse has blown, investigate the
cause, take appropriate action, then replace the fuse.
Table 2.7.11 (b) Capacity and specification of the I/O module fuse for
connector
Capacity
Specification
1.0A A03B0815K002
I/O Link cables
Cable for manual pulse generator
Basic module
(A03B0815C001)
Expansion module 1
Expansion module 2
Expansion module 3
Fuse
CAUTION
The expansion modules have no fuse. A fuse is provided
only for the basic module.
2.7.11
Panel I/O Module for
Connector