3. INPUT AND OUTPUT OF DATA
B63175EN/03
234
1. Set to emergency stop state.
2. Press
OFFSET
SETTING
key several times or press soft key [SETING] to display
SETTING (HANDY) screen.
3. Set the cursor to PARAMETER WRITE and, press
1
and
INPUT
keys in this order. Here alarm 100 will be displayed.
4. Press
SYSTEM
key several times to display the following screen.
PARAMETER (SETTING) O1234N12345
0000 SEQ INI ISO TVC
00000000
0001
00000000
0012 RMV MIR
X00000000
Y00000000
Z00000000
B00000000
0020 I/O CHANNEL
MDI **** *** *** 10:15:30
[ F SRH ][ READ ][ PUNCH ][DELETE ][ ]
To make the cursor display in bit unit,
press the cursor key or .
5. Press soft key[(OPRT)] and the following operation menu is
displayed.
1) Soft key [NO. SRH] :Searched by number.
Examination) Parameter number [NO. SRH].
2) Soft key [ON : 1] : Item with cursor position is set to 1
(bit parameter)
3) Soft key [OFF : 0] : Item with cursor position is set to 0
(bit parameter)
4) Soft key [+INPUT] : Input value is added to the value at cursor
(word type)
5) Soft key [INPUT] : Input value is replaced with the value at
cursor (word type)
6) Soft key [READ] : Parameters are input from reader/puncher
interface.
7) Soft key [PUNCH] : Parameters are output to reader/puncher
interface.