Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
3. INPUT AND OUTPUT OF DATA
237
The Power Mate i memorized the following data.
Save a backup copy of the latest data to the flash memory card or an I/O
unit beforehand, while the controller is running normally.
(1)CNC paramter
(2)PMC parameter
(3)Pitch error compensation amount
(4)Custom macro variable values
(5)Tool compensation amount (offset data)
(6)Part program (machining program, macro program)
(7)Ladder program
Be sure that data input/output cannot be done in an alarm status.
The parameters necessary for data input/output are as follows:
#7
0000
#6 #5 #4 #3 #2 #1
ISO
#0
ISO 0 : Output with EIA code
1 : Output with ISO code (FANUC cassette)
0020 Selection of I/O channel
0 : Channel 1
1 : Channel 1
2 : Channel 2
If the I/O CHANNEL is 0, the relevant parameters are Nos. 101, 102, and
103.
If the I/O CHANNEL is 1, the relevant parameters are Nos. 111, 112, and
113.
If the I/O CHANNEL is 2, the relevant parameters are Nos. 121, 122, and
123.
#7
NFD0101
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
NFD 0 : Feed is output when data is output.
1 : Feed is not output when data is output.
ASI l 0 : EIA or ISO code is used for input data.
1 : ASCII code is used.
SB2 0 : No. of stop bits is 1.
l 1 : No. of stop bits is 2.