Fanuc Power Mate i-D/H Maintenance Manual

3. INPUT AND OUTPUT OF DATA
B63175EN/03
238
0102 pecification number of input/output device
Table 3.2.1 Set value and Input/Output Device
Set value
Input/Output device
0 RS232C (except the following for connection with a PC)
3 FANUC Handy File
NOTE
If I/O CHANNEL = 2 (parameter No. 122), it is impossible to
use the input/output units at set value 3.
0103 Baud Rate
7: 600 9: 2400 11: 9600
8: 1200 l10: 4800 12: 19200 [BPS]
1. Select EDIT mode.
2. Execute file heading when required.
For which file the parameter is output to refer to Explanations (Output
to a floppy).
3. Press
SYSTEM
key and soft key [PARAM] to display parameter screen.
4. Press soft key [(OPRT)], and soft key
.
5. Press soft key [PUNCH] and [EXEC], and the parameters are started
to be output.
1. Select EDIT mode.
2. Execute file heading when required.
As for the file that the parameter is output to, refer to Explanations
(Output to a floppy).
3 Select the parameter display screen by [DGNOS/PARAM] key.
4. Press the [WRITE] key.
5. While parameters are being output, the display appears as below.
> &0100 00000000
WRT
6. In order to stop output of data from a tape before it has finished, turn
on external reset signal ERS (bit 7 of G008).
Once data output from a tape has been stopped, it cannot be restarted.
3.2.2
Outputting CNC
Parameters
Procedure (CRT/MDI)
Procedure (DPL/MDI)

Leave a Reply