Fanuc Power Mate i-D/H Maintenance Manual

3. INPUT AND OUTPUT OF DATA
B63175EN/03
240
11.In DEVICE item, press soft key [FDCAS]. (for handy file)
12.In KIND DATA item, press soft key [PARAM].
13.In FUNCTION item, press soft key [WRITE].
14.In FILE No item, specify a file name. In this example input as follows:
# P
M
C
INPUT
15.Press soft key [EXEC]. Then PMC parameters are started to be output.
16.After the PMC parameters have been output, set PARAMETER
WRITE to 0.
17.Press
RESET
to release alarm 100.
1. Select EDIT mode.
2. Press [VAR] key several time then select a setting screen.
3. Set the cursor to PWE and input
1
and
INPUT
. At this time, alarm
100 will be generated.
4. Press [DGNOS/PARAM] key several time to select diagnosis screen.
5. Press <R/K>,<17> (SB5) or <900> (SB6) and
INPUT
key.
6. Set the first bit to 1.
X X X X X X
1
X
INPUT
Where, mark x is a former value
7. Display the PMC parameter. Press [No] key. Then set file number.
8. Press [WRITE]. Then PMC parameter output starts.
9. After the PMC parameters have been output, set PWE to 0.
10.Reset Power Mate to release alarm 100.
1. Select EDIT mode.
2. Press
SYSTEM
key several times, press soft key [PARAM], and
[PITCH] to select the SETTING screen for pitch error amount.
3. Press soft key [(OPRT)] and
.
4. Press soft key [PUNCH] and [EXEC], then pitch error compensation
amount is started to be output.
1. Select EDIT mode.
2. Execute file heading when required.
3. Select the Pitch Error Compensation data display screen by pressing
[DGNOS/PARAM] key.
4. Press [WRITE] key.
Procedure (DPL/MDI)
3.2.4
Outputting Pitch Error
Compensation Amount
Procedure (CRT/MDI)
Procedure (DPL/MDI)