Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
3. INPUT AND OUTPUT OF DATA
241
1. Select EDIT mode.
2. Press
OFFSET
SETTING
key.
3. Press
key and soft key [MACRO] to select custom macro
variable screen.
4. Press soft key [(OPRT)] and then key
.
5. Press soft key [PUNCH] and [EXEC], then custom macro variable
values are output.
1. Select EDIT mode.
2. Select the custom macro variable display screen by pressing [VAR]
key.
3 Press the [WRITE] key.
4. While the custom macro variables are being output, the display
appears as below.
> #0100
WRT
5. In order to stop output of data from a tape before it has finished, turn
on external reset signal ERS (bit 7 of G008).
Once data output from a tape has been stopped, it cannot be restarted.
1. Select EDIT mode.
2. Press
OFFSET
SETTING
key and soft key [OFFSET] to display the tool
compensation amount screen.
3. Press [(OPRT)] key and soft key
.
4. Press soft key [PUNCH] an [EXEC] key, and the tool compensation
amount is started to be output.
1. Select EDIT mode.
2. Select the offset data display screen by pressing [VAR] key.
3 Press the [WRITE] key.
4. While offset data are being output, the display appears as below.
> H100= 0.000
WRT
3.2.5
Outputting Custom
Macro Variable Values
Procedure (CRT/MDI)
Procedure (DPL/MDI)
3.2.6
Outputting Tool
Compensation Amount
Procedure (CRT/MDI)
Procedure (DPL/MDI)