Fanuc Power Mate i-D/H Maintenance Manual

3. INPUT AND OUTPUT OF DATA
B63175EN/03
242
5. In order to stop output of data from a tape before it has finished, turn
on external reset signal ERS (bit 7 of G008).
Once data output from a tape has been stopped, it cannot be restarted.
1. Confirm the following parameters. If 1 is set, set to the MDI mode and
set it to 0.
#7
0101
#6 #5 #4
NE9
#3 #2 #1 #0
NE8
NE9 l 0 : Programs of 9000s are edited.
1 : Programs of 9000s can be protected.
NE8 l 0 : Programs of 8000s are edited.
1 : Programs of 8000s can be protected.
2. Select EDIT mode.
3. Press PROG key and press soft key [PRGRM] to display program
text.
4. Press [(OPRT)] key and press soft key
.
5. Input a program number to be output. To output all programs input as:
O
9 9 9 9
6. Press [PUNCH] and [EXEC] key, then program output is started.
A program registered in memory can be punched using the procedure
below.
1. Confirm parameter as like above 1.
2. Select EDIT mode.
3. Press [PRGRM] to display the program screen.
4. Key in address O.
5. Key in a desired program number.
Entering < ><9>,<9>,<9>,<9> causes all programs in memory to be
output.
6. The number of input program is punched with pushing [WRITE].