3. INPUT AND OUTPUT OF DATA
B63175EN/03
244
CAUTION
For a system using an absolute pulse coder, reference
position setting is required once all parameters have been
input.
1. Set to the emergency stop state.
2. Press
SYSTEM
key and soft key [PARAM] to display parameter screen.
3. Press soft key [(OPRT)] and soft key
.
4. Press soft key [READ] and [EXEC]. Then input of parameters are
started.
5. After parameter input is completed, P/S alarm 000 will occur. Switch
the power off and on again.
6. Alarm 300 is issued if the system employs an absolute pulse coder.
In such a case, perform reference position return again.
1. Press the EMERGENCY STOP button on the machine side.
2. Press [VAR] key several time then select a setting screen.
3. Set the cursor to PWE and input
1
and
INPUT
. At this time, alarm
100 will be generated.
4. The parameter screen is selected by pressing the [DGNOS/PARAM]
key.
5. Press [READ] key.
6. NC parameters are input to the memory by this operation. Normally,
PS alarm 000 will activate after completion of parameter reading.
7. Set PWE on the setting parameter to 0.
8. Turn on the Power Mate power again.
9. For a system using an absolute pulse coder, alarm 300 is issued.
Perform zero point setting.
1. Set the emergency stop state.
2. Turn off (KEY4=1) the program protect key.
3. Press
OFFSET
SETTING
key and soft key [SETTING] to select the SETTING
screen.
4. Confirm that PARAMETER WRITE=1.
5. Press
SYSTEM
key and soft key [PMC].
6. Press soft key [PMCPRM] and soft key [KEEPRL].
3.2.9
Inputting CNC
Parameters
Procedure (CRT/MDI)
Procedure (DPL/MDI)
3.2.10
Inputting PMC
Parameters