3. INPUT AND OUTPUT OF DATA
B63175EN/03
246
1. Select EDIT mode.
2. The Pitch Error Compensation data screen is selected by pressing the
[DGNOS/PARAM] key.
3. Press [READ] key.
4. Pitch Error Compensation data are input to the memory by this
operation.
1. Confirm that EDIT mode is selected.
2. Turn off the program protect key (KEY2=1).
3. Press
PROG
key then soft key [PRGRM] to display program contents.
4. Press soft key [(OPRT)],
, [F SRH], and
4
[EXEC] to select
a file.
5. Press soft key [(OPRT)] and key
.
6. Press address
O
, a program number (0001 for example), soft key
[READ] and [EXEC] key, then custom macro variable values are
started to be input.
Input a program number that is not used.
7. Select MEMORY mode on the machine operators panel and press
cycle start button.
When the program is executed, macro variables are set.
8. Press
OFFSET
SETTING
key, key and soft key [MACRO] to select the custom
macro variable screen.
9. Press 500 and soft key [NO SRH] to display variable number 500 and
confirm the custom macro variables are set correctly.
Of the data displayed, 0 and vacant differ in meaning.
Vacant is an undefined variable. To set vacant, press soft key
[INPUT].
10.Select EDIT mode again.
11.Press
PROG
key to select the program display screen.
12.Press address O and a program number (0001 for example) ,then press
DELETE
to delete the program.
1. Select EDIT mode.
2. Perform the same operation as for program input and read in the
custom macro statements as a part program.
3. After reading is finished, select AUTO mode. By executing the
program that was read in, the values of the common variables will be
stored in the memory of macro variable.
Procedure (DPL/MDI)
3.2.12
Inputting Custom Macro
Variable Values
Procedure (CRT/MDI)
Procedure (DPL/MDI)