3. INPUT AND OUTPUT OF DATA
B63175EN/03
250
To input/output a particular type of data, the corresponding screen is
usually selected. For example, the parameter screen is used for parameter
input from or output to an external input/output unit, while the program
screen is used for program input or output. However, programs,
parameters, offset data, and macro variables can all be input and output
using a single common screen, that is, the ALL IO screen.
This function cannot be used with a combination of the DPL/MDI and its
operation package.
READ/PUNCH (PROGRAM) O1234 N12345
MDI
*
* * * * * * * * * * * *
12:34:56
PRGRM PARAM OFFSET (OPRT)
I/O CHANNEL 1 TV CHECK OFF
DEVICE NUM. 0 PUNCH CODE ISO
BAUDRATE 4800 INPUT CODE ASCII
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON BAUDRATE CLK. INNER
CD CHECK (232C) OFF RESET/ALARM ON
PARITY BIT OFF SAT COMMAND HOST
INTERFACE RS232C COM PROTCOL A
END CODE EXT COM CODE ASCII
(0:EIA 1:ISO)>1_
MACRO
Fig. 3.3 ALL IO screen (when channel 1 is being
used for input/output)
3.3
DATA INPUT/OUTPUT
ON THE ALL IO
SCREEN