Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
3. INPUT AND OUTPUT OF DATA
257
Offset data can be input and output using the ALL IO screen.
Inputting offset data
1 Press soft key [OFFSET] on the ALL IO screen, described in Section
3.3.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. Soft keys change as shown below.
READ PUNCH
4 Press soft key [READ], then [EXEC].
The offset data is read, and the INPUT indicator blinks at the
lowerright corner of the screen.
Upon the completion of input, the INPUT indicator is cleared from
the screen.
To cancel input, press soft key
[CAN].
Outputting offset data
1 Press soft key [OFFSET] on the ALL IO screen, described in Section
3.3.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. Soft keys change as shown below.
READ PUNCH
4 Press soft key [PUNCH], then [EXEC].
The offset data is output, and the OUTPUT indicator blinks at the
lowerright corner of the screen. Upon the completion of output, the
OUTPUT indicator is cleared from the screen.
To cancel output, press soft key
[CAN].
3.3.4
Inputting and
Outputting Offset Data
Procedure
EXECCAN
Procedure
EXECCAN