258
Custom macro common variables can be output using the ALL IO screen.
Outputting custom macro common variables
1 Press soft key [MACRO] on the ALL IO screen, described in Section
3.3.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. Soft keys change as shown below.
READ PUNCH
4 Press soft key [PUNCH], then [EXEC].
The custom macro common variables are output, and the OUTPUT
indicator blinks at the lowerright corner of the screen. Upon the
completion of output, the OUTPUT indicator is cleared from the
screen.
To cancel output, press soft key
[CAN].
NOTE
To input a macro variable, read the desired custom macro
statement as a program, then execute the program.
3.3.5
Outputting Custom
Macro Common
Variables
Procedure
EXECCAN