Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
3. INPUT AND OUTPUT OF DATA
273
Reading a file
1 Select EDIT mode.
2 Press function key
PROG
.
3 Press the rightmost soft key (continuous menu key).
4 Press soft key
[CARD]. Then, the screen shown below is displayed.
PROG (OPRT)DIR +
DIRECTORY (MCARD)
No. FILE NAME SIZE DATE
O0034 N00045
0001 O1000 123456 96/07/10
0002 O1001 118458 96/07/30
0003 O0002 113250 96/07/30
0004 O2000 173456 96/07/31
0005 O2001 113444 96/07/31
0006 O3001 118483 96/08/02
0007 O3300 111406 96/08/05
0008 O3400 112420 96/07/31
0009 O3500 117460 96/07/31
~ ~
5 Press soft key [(OPRT)].
6 To specify a file number, press soft key
[F READ]. The screen shown
below is displayed.
F NAME EXECSTOPO SET CAN
DIRECTORY (MCARD)
No. FILE NAME COMMENT
O0001 N00010
0019 O1000 (MAIN PROGRAM)
0020 O1010 (SUBPROGRAM1)
0021 O1030 (COMMENT )
~ ~
READ
FILE NAME=20 PROGRAM No.=120
>
EDIT 15:40:21
*
* * * * * * * * * * * * *
7 Enter file number 20 from the MDI panel, then set the file number by
pressing soft key
[F SET]. Next, enter program number 120, then set
the program number by pressing soft key
[O SET]. Then, press soft
key
[EXEC].
File number 20 is registered as O0120 in the CNC.
Set a program number to register a read file with a separate O
number. If no program number is set, the O number in the file name
column is registered.
Procedure
DELETEPUNCHF SRH F READ N READ