Fanuc Power Mate i-D/H Maintenance Manual

4. INTERFACE BETWEEN NC AND PMC
B63175EN/03
288
1. Press
SYSTEM
.
2. Press soft key [PMC], then PMC screen is displayed and the following
soft keys are displayed:
PMC CONTROL SYSTEM MENU MONIT RUN
SELECT ONE OF FOLLOWING SOFT KEYS
PMCLAD : DYNAMIC LADDER DISPLAY
PMCDGN DIAGNOSIS FUNCTION:
PMCPRM PARAMETER (T/C/K/D):
RUN/STOP RUN/STOP SEQUENCE PROGRAM:
EDIT EDIT SEQUENCE PROGRAM:
I/O I/O SEQUENCE PROGRAM:
SYSPRM SYSTEM PARAMETER:
PMCLAD PMCDGN PMCPRM
When
builtin
program-
mer is run-
ning.
System parameter screen
Status display of PMC I/O signal
Dynamic display of sequence program
STOP EDIT I/O SYSPRM
System parameter screen
Input/output of sequence pro-
gram
Editing sequence program
RUN/STOP of sequence
The no. of menus to be displayed changes depending on presence/
absence of builtin programmer.
PMCSB5/SB6
(Without memory card for
editing)
PMCSB5/SB6
(With memory card for
editing)
RUN/STOP f f
EDIT × f
I/O f f
SYSPRM × f
× : Cannot be displayed nor used.
4.3
PMC SCREEN
(CRT/MDI)
4.3.1
Display Method