Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
4. INTERFACE BETWEEN NC AND PMC
291
The setting address, condition and counter are displayed at the title line.
MODE:ON : X0000. 0 : 0 : 0001
COUNT: Trigger checking number (default 1)
POINT: Trigger checking number (default 0)
0 : the top of the 1st level
1 : after END1 execution
2 : after END2 execution
ADR: Trigger setting address
ON: Rising edge detection (TRGON)
OFF: Falling edge detection (TRGOFF)
* Setting form adr ;p1 ;p2+[TRGON/TRGOFF]soft key
NOTE
;=EOB adr (trigger address) ;p1 (trigger point) ;p2 (trigger
checking number (1 to 65535))
* Because parameters are stored in the nonvolatile memory, they are not
lost even if the power is turned off.
When bit 2 of keep relay K18 or K901 is set to 1 after parameters for
sampling are specified, the trigger function automatically starts when
the power is turned on.
For this operation, depress [TRIGER] soft key to bring the following
menu.
SEARCH ADRESS TRIGER WINDOW
NEXT
TRGON TRGOFF START
DUMP DPARA TRGSRC INIT
RET
The function of the [TRIGER] soft key is explained below:
(1)[TRGON] : The trigger function is stopped when a specified
address signal goes high (is turned ON).
(2)[TRGOFF] : The trigger function is stopped when a specified
address signal goes low (is turned OFF).
(3)[START] : Pressing this key switches between trigger function
execution and trigger function termination. While the
trigger function is being executed, the TRG
indication blinks.
(4)[TRGSRC] : An instruction at which the trigger function has been
stopped by a specified address signal is searched for
and indicated by blinking.
(5)[INIT] : The trigger setting is initialized.
D Display of setting trigger