Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
4. INTERFACE BETWEEN NC AND PMC
305
This operation is done usually when a sequence program is prepared.
When PMC parameters are set, internal parameters are not affected.
PARAMETER
#7
K019
#6 #5 #4 #3 #2 #1 #0
0 : Binary format
1 : BCD format
0 : Without protection for input
1 : With protection for input
0 : Binary or BCD format (when bit 0 is valid)
1 : HEX format (when bit 0 is invalid)
TYPE
0 : 1byte length 1 : 2byte length 2 : 4byte length
e. Using the page key
PAGE
/
PAGE
, next screen/previous screen can be
selected.
2 Data display screen
PMC PRM (DATA) 001/001
C.DATA
GSRCH SEARCH
MONIT RUN
Group number
NO. ADDRESS DATA
000 D0000 0
001 D0001 0
002 D0002 0
003 D0003 0
004 D0004 0
005 D0005 0
006 D0006 0
007 D0007 0
008 D0008 0
009 D0009 0
Page number
a. Soft key [C.DATA] :Returns to the data table setting screen.
(Previous screen)
b.
Group No. [GSRCH]: Head of the specified group is selected.
c.
Address [SEARCH]: Searches an address in a group currently
selected.