Fanuc Power Mate i-D/H Maintenance Manual

4. INTERFACE BETWEEN NC AND PMC
B63175EN/03
308
To operate the PMC programmer, set K17#1(PMCSB5) or K900#1=1
(PMCSB6) of the keep relay area for PMC parameters to 1, then press
the [PRGRM] key two times on the DPL/MDI (press the [PRGRM] key
further when the program screen is selected), thus causing the PMC
programmer menu to be displayed.
Program screen
<O0001> N010 G90
G01 G43 X10;
PRGRM
PMC programmer menu screen
PMC PRG MENU 1/4
>RUN/STOP
Can be switched only when K17#1=1 or K900#1=1
To return to the CNC screen, press the [POS], [PRGRM],
[DGNOS/PARAM], [VAR], or [ALARM] key
PMC programmer screen
(PMC programmer menu)
(PMC editing menu)
Current
Position screen
Program screen
Alarm/Message screen
Parameter/Diagnostic
screen
Offset/Setting/Macro
Variable screen
<POS>
<PRGRM>
<ALARM>
<DGNOS/PARAM>
<VAR>
<PRGRM>
(K17#1=1 or K900#1=1)
4.4.1
Selecting the PMC
Programmer Menu