Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
4. INTERFACE BETWEEN NC AND PMC
309
Selecting SYSTEM PARAM on the PMC programmer menu displays the
system parameter screen. If the sequence program is running, selecting
this function automatically stops the program.
1. Display the PMC programmer menu.
2. Display the SYSTEM PARAM item by pressing the [ ] or [ ] key.
PMC PRG MENU 3/4
>SYSTEM PARAM
3. Press the [INPUT] or [READ] key. The system parameter screen
appears.
CTR TYPE=BIN
(BINARY=0/BCD=1)
4. The current counter data type is displayed on the screen.
(a) Specify the type of the counter value to be used for the CTR
functional instruction, as binary or BCD (enter <0> for binary or
<1> for BCD).
(b)Press the [INPUT] key.
The counter data type is set.
5. Pressing the [CAN] or [WRITE] key displays the PMC programmer
menu.
NOTE
1 When K19#0 (SB5) or K902#0(SB6) of the keep relay area
for PMC parameter is set to 1, the screen for storing the
sequence program into FROM is displayed after ladder
editing.
Please refer to the Subsec. 4.4.7 and storing the sequence
program into FROM.
2 In editing the functional instruction TMR, TMRB, CTR,
DIFU, DIFD, the range and the multiple use of parameters
are checked.
When the parameter is out of range error, it can not be
inputted. When parameter is multiple use error, the error
message is displayed on the screen.
(Example) Error message of multiple use.
DEVICE=F ROM
>WRITE Y/N[YES]
N00010 TMR (DUP)
P001 50