4. Relay coil search
Entering [S], [address number], then [ ] searches for the relay
coil including the entered address.
(Example) [WRT], [Y], [3], [3], [.], [5], [ ]
N0187
WRT.NOT Y0033.5
5. Functional instruction search
Entering [SUB],[functional instruction number], then [ ]
searches for the entered functional instruction.
(Example) [SUB], [50], [ ]
N0123
SUB 50 PSGNL
NOTE
1 Relay search, relay coil search, and functional instruction
search are started from the current screen. If the relay, relay
coil, or instruction is not found by the end of the ladder
program, search is performed from the beginning of the
ladder program to the step at which search was started. If
still not found, NOT FOUND is displayed.
2 Display of some instructions may differ from that for FAPT
LADDER.
N0105 NOT FOUND
AND X0000.2
personalcomputer FAPT LADDER
Ladder mnemonics editing
(a) RD.NOT.STK
(b) TMR timernumber
(c) DEC codesignaladdress
(PRM) decodeinstruction
RD.N.STK
SUB 03 TMR
P001 timernumber
SUB 04 DEC
P001 codesignaladdress
P002 decodeinstruction
The above also applies when modifying the ladder mnemonics.
(3)Modifying the ladder mnemonics
1 Changing an instruction
(a) Display the instruction to be changed.
(b)Enter a new instruction.
(c) Press the [ALTER] key.
(Example) [OR], [Y], [3], [2], [.], [4], [ALTER]
N1234
AND R0123.4
Before change