4. INTERFACE BETWEEN NC AND PMC
B63175EN/03
318
D Method of Outputting Ladder
(1)Select Diagnose screen by key in [DGNOS/PARAM] key.
(2)Key in [No.] key.
(3)Key in [WRITE.] key.
D Method of Outputting PMCParameter.
(1)Key in [DGNOS/PARAM] key.
(2)Key in [No.] key and optionally key in [File No.].
(3)Key in [WRITE] key.
NOTE
In case of output PMCParameter, it is necessary to set
following conditions.
1 Edit mode.
2 Stop condition the Ladder program.
If in alarm is issued in the PMC, the alarm message is displayed on the
CRT (PMC ALARM MESSAGE screen). But in case of DPL/MDI, it is
displayed only by Rrelay status (ON or Off).
Refer to the APPENDIX B. ALARM LIST for more information.
Error status at power on or PROGRAM DOWN LOAD.
R9044 #0
#1 : ER01 PROGRAM DATA ERROR
#2 : ER02 PROGRAM SIZE OVER
#3 : ER03 PROGRAM SIZE ERROR (OPTION)
#4 : ER04 LADDER OBJECT TYPE ERROR
#5 : ER05 PMC MODULE TYPE ERROR
#6 : ER06 PMC CONTORL SOFTWARE TYPE UNMATCH
#7 : ER07 NO OPTION (LADDE STEP)
R9045 #0 : ER08 OBJECT UNMATCH
#1 : ER09 PMC LABEL CHECK ERROR
#2 : ER10 OPTION AREA OUT OF RANGE
#3 :
#4 : ER12 OPTION AREA ERROR
#5 :
#6 : ER14 OPTION AREA VERSION ERROR
#7 :
R9046 #0 : ER16 RAM CHECK ERROR (PAROGRAM RAM)
#1 : ER17 PROGRAM PARITY
#2 : ER18 PROGRAM DATA ERROR BY I/O
#3 : ER19 LADDER DATA ERROR
#4 : ER20 SYMBOL/COMMENT DATA ERROR
#5 : ER21 MESSAGE DATA ERROR
#6 : ER22 PROGRAM NOTHING
#7 : ER23 PLEASE TURN OFF POWER
4.4.9
Error List