4. INTERFACE BETWEEN NC AND PMC
345
PM iHPM iDAddressSignal nameSymbol
+EDITA G462#0 f f
+EDITB G462#1 f f
+EDITC G462#2 f f
+EDITD
Axis directionspecific interlock forward signal
G462#3 f f
+EDITE
Axis directionspecific interlock forward signal
(PMC axis control)
G462#4 f f
+EDITF G462#5 f f
+
+EDITG G462#6 f f
+EDITH G462#7 f f
+J1 to +J8 Feed axis and direction selection signals G100 f f
+J1O to +J4O Software operators panel signals (+J1 to +J4) F081#0,#2,#4, #6 f f
+LM1 to +LM8 Stroke check external setting signals G110 f f
+MIT1 to +MIT8 Interlock signal for each axis and direction G132 f f
EDITA G463#0 f f
EDITB G463#1 f f
EDITC G463#2 f f
EDITD
Axis directionspecific interlock backward signal
G463#3 f f
EDITE
Axis directionspecific interlock backward signal
(PMC axis control)
G463#4 f f
EDITF G463#5 f f
EDITG G463#6 f f
EDITH G463#7 f f
J1 to J8 Feed axis and direction selection signals G102 f f
J1O to J4O Software operators panel signals (J1 to J4) F081#1,#3,#5, #7 f f
LM1 to LM8 Stroke check external setting signals G112 f f
MIT1 to MIT8 Interlock signal for each axis and direction G134 f f
ABTQSV Servo axis abnormal load detected signal F090#0 f f
ABTSP1 Firstspindle abnormal load detected signal F090#1 f
ACT Temporary interrupt detection signal G212#7 f f
AD02 to AD15,
ADSGN
Analog input signal F206 to F207 f
A
AFL Auxiliary function lock signal G005#6 f f
AL Alarm signal F001#0 f f
ALAPC APC alarm signal F251#0 f f
ALMA Alarm signals (serial spindle) F045#0 f
ALOH Over heat alarm signal F250#5 f f