Fanuc Power Mate i-D/H Maintenance Manual

5. DIGITAL SERVO
B63175EN/03
372
D MAINTENANCE NO. (engineering change number for an amplifier
connected to each axis)
On an FSSB setting screen (other than the amplifier maintenance screen),
pressing soft key [(OPRT)] displays the following soft keys:
SET INPUTREAD
To enter data, place the machine in MDI mode or the emergency stop state,
position the cursor to the point where a desired item is to be input, then
enter the desired data and press soft key [INPUT] (or the
INPUT
key on the
MDI panel).
When soft key [SET] is pressed after data has been entered, a warning
message is displayed if the entered data contains an error. When the data
is satisfactory, the corresponding parameter is set up.
To restore the previous value of a parameter if, for example, an entered
value is incorrect, press soft key [READ].
When the power is turned on, values are read from the parameters and
displayed on the screen.
NOTE
1 For the parameters to be specified on the FSSB setting
screen, do not attempt to enter values on the parameter
screen using the MDI or a G10 command. Use only the
FSSB screen to enter values for these parameters.
2 If pressing soft key [SET] results in a warning message
being displayed, retry data entry, or press soft key [READ]
to clear the warning message. Note that pressing the reset
key does not clear the warning message.
3 This function cannot used with the twopath control function
of the Power Mate iD.
1) Amplifier setting screen
AMPLIFIER SETTING O1000 N00001
NO. AMP SERIES UNIT CUR. AXIS NAME
1A1L α SVMHV 40AL 1 X
2A1M α SVM 12A 2 Y
3A2L β SVM 40A 3 Z
4A3L α SVM 20A 4 A
5A3M α SVM 40A 5 B
7A4L α SVU 240A 6 C
NO. EXTRA TYPE PCB ID
6 M1 A 0000 DETECTOR(8AXES)
8 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[SETTING][ ][ READ ][ ][ INPUT ]