Fanuc Power Mate i-D/H Maintenance Manual

7. TROUBLESHOOTING
B63175EN/03
414
(3)Manual handle feed multiplication is not correct
Check the following signals using PMCs PMCDGN. Also confirm
the following parameters based on the parameter list.
#7
G0019
#6 #5
MP2
#4
MP1
#3 #2 #1 #0
↓↓
MP2 MP1 Multiplication
0 0 1
1 0 10
0 1 m
1 1 n
7110 No. of MPGs used (1 to 3)
7113 Magnification of handle feed m (1 to 127)
7114 Magnification of handle feed n (1 to 1000)
(4)Checking manual pulse generator
(a) Incorrect of cable
Check disconnection of cable or short circuit.
(1)Connection with the Power Mate main unit
Power Mate
MPG (JA47)
1st MPG
2nd MPG
#1
#2
HA1
HB1
+5V
0V
HA2
HB2
+5V
0V
(01)
(02)
(09)
(12)
(03)
(04)
(18)
(14)
HA1
HB1
+5V
0V
HA2
HB2
+5V
0V
Power Mate (JA47)
Manual pulse
generator
(A)
(B)
(+5V)
(0V)
(A)
(B)
(+5V)
(0V)
1st
2nd
shield