Fanuc Power Mate i-D/H Maintenance Manual

7. TROUBLESHOOTING
B63175EN/03
422
When signal MDTHn is 1 ,the axis detach function is in valid.
The control axis detach function becomes valid by the following
signal issued from the PMC or a parameter. Check as in the following
procedure :
1) The control axis detach signal (DTCHn) is input.
#7
DTCH8G0124
#6
DTCH7
#5
DTCH6
#4
DTCH5
#3
DTCH4
#2
DTCH3
#1
DTCH2
#0
DTCH1
If it is 1, the corresponding axis is detached.
2) The following parameter enables the control axis detach function to
the corresponding axis.
#7
RMVx0012
#6 #5 #4 #3 #2 #1 #0
RMVx 0 : Controlled axis is connected
1 : Controlled axis is detached
Actual spindle speed does not arrive at a speed specified in a program.
Confirm the signal state using the PMCs diagnostic function
(PMCDGN).
#7
G0029
#6 #5 #4
SAR
#3 #2 #1 #0
SAR : When this signal is 0, spindle speed does not arrive at the specified speed.
This function is valid when parameter No. 3708#0=1.
Normally manual feedrate override function is used for jog feed.
But when DRN (dry run) signal turns on during an auomatic operation,
override values set with these signals become valid to the following speed
set by a parameter.
#7
DRNG0046
#6 #5 #4 #3 #2 #1 #0
DRN : Dry run signal is input with this signal being 1.
1410 Dry run rate
The rate when the following override value is 100%.
#7
*JV7G0010
#6
*JV6
#5
*JV5
#4
*JV4
#3
+JV3
#2
*JV2
#1
*JV1
#0
*JV0
↓↓
*JV15G0011 *JV14 *JV13 *JV12 +JV11 *JV10 *JV9 *JV8
When override value is 0%, all bits of the above address is
[1111 1111] or [0000 0000].. . . . . . . . . . . . . .
*JV15 JV0. . . . . . . . . . . . . . Override
1111 1111 1111 1111
1111 1111 1111 1110
1101 1000 1110 1111
0000 0000 0000 0001
0000 0000 0000 0000
0.00%
0.01%
:
100.00%
:
655.34%
0.00%
g.CNC is waiting for
spindle speed arrival
signal to be input
h.Manual feedrate override
is 0% (dry run)