Fanuc Power Mate i-D/H Maintenance Manual

1. DISPLAY AND OPERATION
B63175EN/03
20
Types of PCBs mounted on the slots are displayed.
If a hardware trouble or an incorrect mounting is found, this screen is
displayed.
SLOT CONFIGURATION DISPLAY
0: 003E4000 0:
1: 30464202 1:
2: 00504303 2:
3: 3:
4: 4:
5: 5:
Physical slot number (2ndary side)
Module ID of the PCB mounted (*1)
Physical slot number (primary side)
*1) Module ID of PCB
Internal slot number
Module function (software ID)
Type of PCB (module ID)
ff j j
ID Name
DD Power Mate i base PCB
AA Highspeed serial bus (HSSB) board
C4 or 95 FANUC I/O LinkII board
E3 PROFIBUSDP slave board
FC PROFIBUSDP master board
36 Ethernet board
EF DeviceNet slave board (B)
DeviceNet master board (B)
59 FLnet board
BF DeviceNet slave board (C)
40 : Basic function
1.2
SCREEN DISPLAYED
IMMEDIATELY AFTER
POWER IS TURNED
ON
1.2.1
Slot Status Display
D Slot state screen
D Module ID
D Software ID