Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
7. TROUBLESHOOTING
459
For an explanation of the following SPC alarms (serial pulse coder
alarms), refer to the FANUC SERVO MOTOR α Series Maintenance
Manual (B65165E).
Number Message Contents *
360 n AXIS: ABNORMAL CHECKSUM (INT) A checksum error occurred in the builtin
pulse coder.
350
361 n AXIS: ABNORMAL PHASE DATA (INT) A phase data error occurred in the builtin
pulse coder.
362 n AXIS: ABNORMAL REV. DATA (INT) A rotation speed count error occurred in the
builtin pulse coder.
363 n AXIS: ABNOMAL CLOCK (INT) A clock error occurred in the builtin pulse
coder.
364 n AXIS: SOFT PHASE ALARM (INT) The digital servo software detected invalid
data in the builtin pulse coder.
365 n AXIS: BROKEN LED (INT) An LED error occurred in the builtin pulse
coder.
366 n AXIS: PULSE MISS (INT) An LED error occurred in the builtin pulse
coder.
367 n AXIS: COUNT MISS (INT) A count error occurred in the builtin pulse
coder.
368 n AXIS: SERIAL DATA ERROR (INT) Communication data from the builtin pulse
coder cannot be received.
351
369 n AXIS: DATA TRANS. ERROR (INT) A CRC or stop bit error occurred in the com-
munication data being received from the
builtin pulse coder.
NOTE
The alarm numbers mentioned in the above manual are
those shown in the * column.
For an explanation of the following spindle alarms, refer to the FANUC
CONTROL MOTOR α Series Maintenance Manual (B65165).
Number Contents *
7101 to 7199 Spindle alarm (AL01 to 99) 751
NOTE
The alarm numbers mentioned in the above manual are
those shown in the * column.
7.36
SPC ALARMS
7.37
SPINDLE ALARMS