Fanuc Power Mate i-D/H Maintenance Manual

7. TROUBLESHOOTING
B63175EN/03
462
On the system alarm screen, alarm 926 is displayed as well as additional
information displayed in the lower part of the screen as follows:
NMIC 11100000 00100000 11110111 11111111
00000001 10000000 01010100 00010101
15 --- 8 7 --- 0 15 --- 8 7 --- 0
Bit Bit
Mode
information
Status
information
Bits 12 to 15 of the mode information indicate the number of a slave where
the alarm was generated. Slave numbers are assigned to units starting
with slave number 0 which is assigned to the unit nearest the CNC. For
a 2axis amplifier, a slave number is assigned to each of the first and
second axes by incrementing the number.
Details of mode information
Bit 15 14 13 12 11 0
Meaning Slave number at which alarm was
generated
No meaning
0000: The alarm was generated from slave 0.
0001: The alarm was generated from slave 1.
:
:
1001: The alarm was generated from slave 9.
Details of status information
Bit 15 12 11 10 9 8 7 6 5 4 3 0
Meaning No meaning External
alarm
Broken
wire in
master
port
Broken
wire in
slave
port
No
meaning
Broken
wire in
master
port
No
meaning
Error in
slave
A X X X X 0 0 0 X X 1 X 0 X X X X
A X X X X 0 1 0 X X 0 X 1 X X X X
B X X X X 0 0 1 X X 0 X 1 X X X X
C X X X X 1 0 0 X X 0 X 1 X X X X
The status information matches one of the data patterns A, B, and C above.
According to this information, take appropriate action for A, B, and C described below.
(x means that the value can be 0 or 1.)
D Determining a faulty
location from the screen
displayed on the CNC

Leave a Reply