Fanuc Power Mate i-D/H Maintenance Manual

APPENDIX
B63175EN/03
A. ALARM LIST
471
Number ContentsMessage
031 ILLEGAL P COMMAND IN G10 In setting an offset amount by G10, the offset number following address
P was excessive or it was not specified.
Modify the program.
032 ILLEGAL OFFSET VALUE IN G10 In setting an offset amount by G10 or in writing an offset amount by
system variables, the offset amount was excessive.
Check and correct the offset amount.
044 G27G30 NOT ALLOWED IN FIXED
CYC
One of G27 to G30 is commanded in canned cycle mode.
Modify the program.
046 ILLEGAL REFERENCE RETURN
COMMAND
Other than P2 and P3 are commanded for 2nd and 3rd reference
position return command.
059 PROGRAM NUMBER NOT FOUND In an external program number search, a specified program number
was not found. Otherwise, a program specified for searching is being
edited in background processing. Check the program number and
external signal. Or discontinue the background eiting.
060 SEQUENCE NUMBER NOT FOUND Commanded sequence number was not found in the sequence number
search. Check the sequence number.
070 NO PROGRAM SPACE IN
MEMORY
The memory area is insufficient.
Delete any unnecessary programs, then retry.
071 DATA NOT FOUND The address to be searched was not found. Or the program with
specified program number was not found in program number search.
Check the data.
072 TOO MANY PROGRAMS The number of programs to be stored exceeded 63 (basic), 125 (option),
200 (option), or 400 (option). Delete unnecessary programs and
execute program registeration again.
073 PROGRAM NUMBER ALREADY IN
USE
The commanded program number has already been used.
Change the program number or delete unnecessary programs and
execute program registeration again.
074 ILLEGAL PROGRAM NUMBER The program number is other than 1 to 9999.
Modify the program number.
075 PROTECT An attempt was made to register a program whose number was
protected. Check the program number, or cancel protection.
076 ADDRESS P NOT DEFINED Address P (program number) was not commanded in the block which
includes an M98, G65, or G66 command. Modify the program.
077 SUB PROGRAM NESTING ERROR The subprogram was called in five folds. Modify the program.
Modify the program so that the subprogram is called in four folds or less.
078 NUMBER NOT FOUND A program number or a sequence number which was specified by
address P in the block which includes an M98, M99, M65 or G66 was
not found. The sequence number specified by a GOTO statement was
not found. Otherwise, a called program is being edited in background
processing. Correct the program, or discontinue the background
editing.
079 PROGRAM VERIFY ERROR In memory or program collation,a program in memory does not agree
with that read from an external I/O device. Check both the programs in
memory and those from the external device.
085 COMMUNICATION ERROR When entering data in the memory by using Reader / Puncher interface,
an overrun, parity or framing error was generated. The number of bits
of input data or setting of baud rate or specification No. of I/O unit is
incorrect. See Chapter 7.
086 DR SIGNAL OFF When entering data in the memory by using Reader / Puncher interface,
the ready signal (DR) of reader / puncher was off.
The power to the I/O unit may be off, the I/O unit may be defective, or
the cable may be broken. Alternatively, the Power Mate i base
printedcircuit board may be defective. See Chapter 7.