Number ContentsMessage
205 RIGID MODE DI SIGNAL OFF Rigid tapping signal (G061#1) is not 1 when G84 (G74) is executed
though the rigid M code (M29) is specified.Consult the PMC ladder
diagram to find the reason the DI signal is not turned on.
Modify the program.
206 CAN NOT CHANGE PLANE (RIGID
TAP)
Plane changeover was instructed in the rigid mode.
Correct the program.
207 RIGID DATA MISMATCH The specified distance was too short or too long in rigid tapping.
213 ILLEGAL COMMAND IN
SYNCHROMODE
Any of the following alarms occurred in the operation with the simple
synchronization control.
1) The program issued the move command to the slave axis.
2) The program issued the manual continuous feed/manual handle
feed/incremental feed command to the slave axis.
3) The program issued the automatic reference position return
command without executing the manual reference position return
after the power was turned on.
4) The difference between the position error amount of the master and
slave axes exceeded the value specified in parameter No. 8313.
214 ILLEGAL COMMAND IN
SYNCHROMODE
Coordinate system is set in the synchronous control. Correct the
program.
224 RETURN TO REFERENCE POINT Reference position return has not been performed before the automatic
operation starts. Perform reference position return only when bit 0
(ZRN
X
) of parameter No. 1005 is 0.
231 ILLEGAL FORMAT IN G10 OR L50 Any of the following errors occurred in the specified format at the
programmableparameter input.
1) Address N or R was not entered.
2) A number not specified for a parameter was entered.
3) The axis number was too large.
4) An axis number was not specified in the axistype parameter.
5) An axis number was specified in the parameter which is not an axis
type.
Correct the specified format.
233 DEVICE BUSY When an attempt was made to use a unit such as that connected via the
RS232C interface, other users were using it.
Wait until the user ends the use of the unit, then use it.
239 BP/S ALARM While punching was being performed with the function for controlling
external I/O units ,background editing was performed.
Wait until external punching terminates, then perform background
editing.
240 BP/S ALARM Background editing was performed during MDI operation.
Wait until MDI operation terminates, then perform background editing.
5010 END OF RECORD The end of record (%) was specified.
5120 NON A/D MODULE Although the analog input module enable parameter is set, no option
card 2 is installed.
5121 A/D MODULE The A/D converter is abnormal. Replace the option card 2.
5134 FSSB : OPEN READY TIME OUT Initialization did not place FSSB in the open ready state.
5135 FSSB : ERROR MODE FSSB has entered error mode.
5136 FSSB : NUMBER OF AMPS IS
SMALL
In comparison with the number of controlled axes, the number of
amplifiers recognized by FSSB is not enough. This occurs also if there
is a poor connection in the FSSB optical cable when the power is
switched on.
5137 FSSB : CONFIGURATION ERROR FSSB detected a configuration error.