Fanuc Power Mate i-D/H Maintenance Manual

APPENDIX
B63175EN/03
A. ALARM LIST
475
Number ContentsMessage
5138 FSSB : AXIS SETTING NOT
COMPLETE
In automatic setting mode, axis setting has not been made yet.
Perform axis setting on the FSSB setting screen.
5139 FSSB : ERROR Servo initialization did not terminate normally.
The optical cable may be defective, or there may be an error in
connection to the amplifier or another module.
Check the optical cable and the connection status.
5150 PARAM (NO. 1011) SETTING
ERROR
The specified maximum number of axes (parameter 1011) to be
controlled is incorrect.
5197 FSSB : OPEN TIME OUT The CNC permitted FSSB to open, but FSSB was not opened.
5198 FSSB : ID DATA NOT READ Temporary assignment failed, so amplifier initial ID information could not
be read.
5222 SRAM CORRECTABLE ERROR A correctable error occurred in the SRAM (ECC).
This does not immediately affect operation. If alarm 935 is issued,
replace the memory module, and restore the SRAM memory data.
5225 ILLEGAL MACRO EXECUTOR A macro library for the Power Mate iMODEL H is registered in the
Power Mate iMODEL D. Alternatively, a macro library for the Power
Mate iMODEL D is registered in the Power Mate iMODEL H.
5226 ILLEGAL C LANGUAGE
EXECUTOR
A C library for the Power Mate iMODEL H is registered in the Power
Mate iMODEL D. Alternatively, a C library for the Power Mate
iMODEL D is registered in the Power Mate iMODEL H.
5240 ALL PROGRAMS HAVE BEEN
DELETED
Because the number of digits of a program number was changed, all the
programs were deleted.
5246 ELECTRONIC CAM PARAMETER
ILLEGAL
An error is found in the following electronic cam parameters. Correct the
setting.
Parameter No. 8086 (cam shaft axis number)
Parameter No. 8087 (followup axis selection)
Parameter No. 8088 (number of cam shape data items)
Bit 0 of parameter No. 1006 (rotation axis setting)
Bit 0 of parameter No. 1008 (rollover setting)
Parameter No. 1260 (travel distance per rotation of the rotation axis)
5247 CAM DATA ILLEGAL D The cam data checksum is illegal.
D The cam shaft phase number of cam data is illegal.
D Cam data transfer failed.
5248 CAM DATA AREA INSUFFICIENT D Because there is no storage option equivalent to 160meter or
longer tape, no area was allocated for cam data registration.
D Because the amount of cam data is too large, the storage area
becomes insufficient.
5249 ELECTRONIC CAM CAN NOT
EXECUTE
Phase matching or electronic cam operation could not be executed for
one of the following reasons:
D Phase matching was performed without storing cam data.
D Electronic cam operation was executed before phase matching was
not completed.
D The electronic cam function was executed while movement along
an axis was being performed by another function.
5261 PMC INDIRECT COMMAND IS
ILLEGAL
An indirect command for PMC axis control is illegal.