Fanuc Power Mate i-D/H Maintenance Manual

APPENDIXA. ALARM LIST
B63175EN/03
488
(1) Alarm messages (PMC)
Message Contents and solution
ALARM NOTHING Normal status
ER01 PROGRAM DATA
ERROR(RAM)
The sequence program is defective.
(solution) Please clear the RAM and input LADDER again.
ER02 PROGRAM SIZE OVER The size of sequence program exceeds the maximum size of LADDER(PMCSC only).
(solution) Please change MAX LADDER AREA SIZE at the SYSPRM screen and
restart the system.
ER03 PROGRAM SIZE
ERROR(OPTION)
The size of sequence program exceeds the option specification size.
(solution) Please increase the option specification size.
Or, reduce the size of sequence program.
ER04 PMC TYPE UNMATCH The PMC model setting of the sequence program is not corresponding to an actual
model.
(solution) Please change the base PC board.
ER05 PMC MODULE TYPE
ERROR
The module type of the PMC engine is not correct.
(solution) Please exchange the module of PMC engine for a correct one.
ER07 NO OPTION
(LADDER STEP)
There is no step number option of LADDER.
ER10 OPTION AREA NOTHING
(series name)
The management software for the PMCSB has not been transferred.
(solution) The software installation is not consistent with the order. Contact FANUC.
ER12 OPTION AREA ERROR
(series name)
The series of the management software for the PMCSB differs between BASIC and
OPTION.
(solution) Contact FANUC.
ER14 OPTION AREA VERSIION
ERROR (series name)
The edition of the management software for the PMCSB differs between BASIC and
OPTION.
(solution) Contact FANUC.
ER17 PROGRAM PARITY The parity error occurred on FROM for sequence program or the RAM.
(solution) ROM: The deterioration of FROM may be deteriorated
Please exchange memory module.
ER18 PROGRAM DATA ERROR
BY I/O
Transferring the sequence program from offline programmer was interrupted by the
power off etc.
(solution) Please clear the sequence program and transfer the sequence program
again.
ER19 LADDER DATA ERROR Editing the LADDER was interrupted by the power off or by the switch to the CNC screen
by the function key etc.
(solution) Please edit LADDER once on PMC.
Or, please input LADDER again.
ER20 SYMBOL/COMMENT
DATA ERROR
Editing the symbol and comment was interrupted by the power off or by the switch to the
CNC screen by the function key etc.
(solution) Please edit symbol and comment once on PMC.
Or, please input symbol and comment again.
A.2
LIST OF ALARMS
(PMC)

Leave a Reply