Fanuc Power Mate i-D/H Maintenance Manual

APPENDIX
B63175EN/03
A. ALARM LIST
489
Message Contents and solution
ER21 MESSAGE DATA ERROR Editing the message data was interrupted by the power off or the switch to the CNC
screen by the function key etc.
(solution) Please edit message data once on PMC.
Or, please input message data again.
ER22 PROGRAM NOTHING There is no sequence program
ER23 PLEASE TURN OFF
POWER
There is a change in setting LADDER MAX AREA SIZE etc.
(solution) Please restart the system to make the change effective.
ER25 SOFTWARE VERSION
ERROR (PMCAOPT)
The PMCSB management software editions are inconsistent.
(solution) Contact FANUC.
ER26 SOFTWARE VERSION
ERROR (PMCAOPT)
The PMCSB management software cannot be initialized.
(solution) Contact FANUC.
ER33 SLC ERROR The LSI for I/O Link is defective.
(solution) Please exchange the base PC board.
ER34 SLC ERROR(xx) The communication with the DI/DO units of the xx group failed.
(solution) Please confirm the connection of the cable connected to the DI/DO units of
the xx group.
Please confirm whether the DI/DO units turned on earlier than CNC and
PMC. Or, please exchange the module of PMC engine on the DI/DO units of
the xx group
ER35 TOO MUCH OUTPUT
DATA IN GROUP(xx)
The number of the output data in the xx group exceeded the max. The data, which
exceed 32 bytes, become ineffective.
(solution) Please refer to the following for the number of the data for each group.
FANUC I/O UnitMODEL A connecting and maintenance manual
(B61813E)
FANUC I/O UnitMODEL B connecting manual(B62163E)
ER36 TOO MUCH INPUT DATA
IN GROUP(xx)
The number of the input data in the xx group exceeded the max. The data, which exceed
32 bytes, become ineffective.
(solution) Please refer to the following for the number of the data for each group.
FANUC I/O UnitMODEL A connecting and maintenance manual
(B61813E)
FANUC I/O UnitMODEL B connecting manual(B62163E)
ER38 MAX SETTING OUTPUT
DATA OVER(xx)
The assignment data for a group exceeds 128 bytes.
(The assignment data of output side of xx group or later become ineffective.)
(solution) Please reduce the assignment data to 128 bytes or less for the number of the
output data of each group.
ER39 MAX SETTING INPUT
DATA OVER(xx)
The assignment data for a group exceeds 128 bytes.
(The assignment data of input side of xx group or later become infective.)
(Solution) Please reduce the assignment data to 128 bytes or less for the number of
the input data of each goup.
*When ER00 to ER26 occur, sequence program is not available.