Alarms generated in the Power Mate are recorded. The latest 50 alarms
generated are recorded. The 50th and former alarms are deleted.
Alarm history cannot be displayed on DPL/MDI or DPL/MDI operation
package.
(1)Press
MESSAGE
key .
(2)Press soft key [HISTRY] and an alarm history screen is displayed.
(3)Other pages are displayed by
PAGE
or
PAGE
key.
ALARM HISTORY O1234 N12345
PAGE:1
97/04/18 20:56:26
506 OVERTRAVEL : +X
97/04/18 19:58:11
000 TURN OFF POWER
97/04/18 19:52:45
000 TURN OFF POWER
97/04/18 19:48:43
300 APC ALARM : XAXIS ZERO RETURN REQUEST
97/04/18 18:10:10
507 OVERTRAVEL : +B
MDI **** *** *** 10:15:28
[ ALARM ][ MSG ][ HISTRY ][ ][(OPRT)]
(1)Press soft key [(OPRT)].
(2)Press soft key [(CLEAR], then the alarm history is cleared.
When an external alarm (No. 1000 to 1999) or a macro alarm (No. 3000
to 3999) is output, the alarm history function can record both the alarm
number and message if so specified in the following parameter. If
recording of the message is not set or if no message is input, only an
external alarm or macro alarm is displayed.
#7
3112
#6 #5 #4 #3
EAH
#2 #1 #0
[Data type] Bit
EAH The alarm history function:
0 : Does not record the messages output with external alarms or macro
alarms.
1 : Records the messages output with external alarms or macro alarms.
1.4
ALARM HISTORY
SCREEN
1.4.1
General
1.4.2
Screen Display
1.4.3
Clearing Alarm History
1.4.4
Alarm Display