Fanuc Power Mate i-D/H Maintenance Manual

1. DISPLAY AND OPERATION
B63175EN/03
30
Mode selection signals and rapid traverse override signals are displayed
as indicated below:
Input signal
MD1 ND2 MD4 ZRN DNCI
Name displayed
0 0 0 0 0 MDI
1 0 0 0 0 AUTO
1 0 0 0 1 RMT
0 1 0 0 0 NOMODE
1 1 0 0 0 EDIT
0 0 1 0 0 STEP
1 0 1 0 0 JOG
1 0 1 1 0 ZRN
0 1 1 0 0 TJOG
1 1 1 0 0 THND
Input signal
ROV1 ROV2
Name displayed
0 0 R 100%
1 0 R 50%
0 1 R 25%
1 1 R F0%
(3)Alarms
Alarms are displayed in reverse video.
P/S alarms, system alarms, and external alarms are displayed together
with their numbers.
For other types of alarms, only the alarm type is displayed. (No details
are displayed.)
For twopath control, the operations of path 2 are displayed in the
same way, but preceded by S_.
Example)
P/S0050, SV_ALM, S_APC_ALM
(4)Time stamp (date and time)
The following time data (date and time) is recorded:
1) Date and time of poweron
2) Date and time of poweroff
3) Date and time when an alarm occurs
4) The clock time is recorded at predetermined intervals, together
with each new calendar day.