Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
F. SETTING/DISPLAY/MAINTENANCE
USING THE MAIN UNIT OF
THE Power Mate i
APPENDIX
553
Follow the procedure explained below to perform setting and
maintenance operation by using the rotary switch (MTSW), pushbutton
switch (PSW), and 7segment LED (LEDM1) on the Power Mate i.
(1)Primary selection (selection by the rotary switch)
Before turning on the power, set a desired number with the rotary
switch. (The rotary switch must be set before the power is turned on.)
When the power has been turned on, the selected rotary switch number
blinks on the 7segment LED if the rotary switch number is set to a
nonzero number. When the pushbutton switch is pressed while the
LED indication is blinking, blinking stops, then the secondary
selection explained below starts.
(2)Secondary selection (selection by the 7segment LED and pushbutton
switch)
After the primary selection operation is completed, numbers that can
be selected for the secondary selection appear on the 7segment LED
in succession. While a desired number appears (for about one second),
press the pushbutton switch. Then, the number blinks (at high speed).
If the selected number is correct, press the pushbutton switch again.
Then, blinking stops, and the secondary selection is completed. If the
selected number is wrong, or if you want to cancel the number
selection, hold down the pushbutton switch for at least three seconds
while the number blinks (at high speed). Then, the selection operation
is canceled, and numbers are again displayed on the 7segment LED
one by one.
(3)Tertiary selection (selection by the 7segment LED and pushbutton
switch) and subsequent operations
When the tertiary selection is required, selectable numbers appear on
the 7segment LED sequentially after the completion of the secondary
selection operation. Select a desired number using the 7segment
LED and pushbutton switch in the same manner as the secondary
selection. The subsequent operations are the same as explained in (2)
above.
To perform the primary selection for another setting item after completing
a selection operation, turn off the power, then perform steps (1) to (3)
above. After completing all the primary selection operations, be sure to
set the rotary switch to 0.
NOTE
Although the rotary switch number setting is possible when
the Power Mate is on, the primary selection is made at
powerup.
Even when a setting/display unit is connected, nothing is displayed on the
screen in the middle of the selection procedure explained above.
F.4
SETTING/
MAINTENANCE
USING THE Power
Mate i MAIN UNIT
F.4.1
Operation at Powerup